Technical

Jump to a Section:

Models

 

Loads on Lintel

LBS Per Lineal Foot

Door Height in Feet
Wind Velocity
75 mph * 100 mph **
Horizontal H Vertical V Horizontal H Vertical V
10117308211447
11126325229473
12138343247499
13150357264519
14159371286543
15171389304563
16183403324583
17192418342603
18204433361624
19213447382645
20228462399661
21237476417682
22245491438699
23258503456720
24267518475738
25279533495755
26289543513779
27300563534797
28311574551816
29321590573836
30332606588857
31340615605880
32350630625900
33362645645918
34371660665937
35384675685958
36394690701978
374037047221000
384157207411020
394257337601040
404357507801060
414487637971080
424577908161096
434687918351116
444808088541135
454908218731155
465008388921176
475108509101195
485218669301215
495328809501233
505438959701250

  • * 75 mph - 20 lbs per sq. ft. curtain area
  • ** 100 mph - 38 lbs per sq. ft. curtain area

To Use the Table:

  • Step 1: Select the line under the column headed “Door Height in feet” corresponding to the door selected.
  • Step 2: Determine the lintel loads on the selected line under the appropriate columns.
  • Step 3: Multiply the values shown by the door opening width in feet plus two feet (Addition two feet is the normal overlap) to determine the lintel loads (Horizontal and Vertical). These figures are the live loads uniformly distributed along the lintel where the curtain is attached. The resulting calculations are the live lintel loads both vertical and horizontal except as noted below.

Note:

The calculated figures in step 3 are the extra load factors to be used in addition to the static and live loads of the building itself.

These figures are based on standard installation instructions and could be higher on non-standard installation or unusual building conditions.

Man Hours for Installation

Door Model Approximate Man Hours
"A" 80 hours
"B" 100 hours
"C" 128 hours
"D" 160 hours

The above figures are approximate and are only to be used as a guide. These figures are based on the assumption that the door opening is ready, the guide rails are installed, and no supports or obstructions are in the way for completing the installation of the door.

Electricity is already installed to a disconnect box at the drive end of the door.

In most installations a welder and electrician are needed for a short time, otherwise, local labor conditions prevail. Installation is made easy with the use of the “Installation & Operating Instructions” manual.

In cases where one or more doors are installed at an installation, the above times can be cut considerably.

Note:

The above hours do not include the installation of the optional Side Door Seals. Please add 24 hours to the above figures when these optional Side Door Seals are used.

Owner's Manual

Download the Para-Port Door Owner's Manual

Installation Manual

Download the Installation Manual

Maintenance & Inspection Sheet

View the Inspection Sheet

Lubrication

  • The roller chains on the drive units should be periodically lubricated with a roller chain lubricant.
  • For motor lubrication, refer to motor manufacturer’s recommendations. See the tag attached to the motors.
  • The oil in all gearboxes should be changed once a year, and in severe operating conditions, more frequently. Use Para-Port Door Part No. 14090090 oil or Mobil #SHC 634. While the oil is drained from the larger gearbox, remove the inspection plate opposite the final output shaft and inspect the gears for cracks, missing teeth and excessive wear.
  • The cam roller bearings that ride on the guide rails and the main shaft support bearings that are at the ends of tube, should be greased at least every six (6) months.
  • The pulleys on the counterweight system, the hinges and toggles on the inside door seals, and the pins and rollers in the portable hold-downs and outside bump rolls, should be lubricated periodically.
  • On the doors using counterweights; the counterweight cables should be greased with a light coating at least every six (6) months.

Maintenance

  • It is recommended that after the door has been in use for a short time, that all nuts and bolts, retainer clips, set screws, etc., be checked and tightened if necessary.
  • The drive chains on the carriage should be properly adjusted at all times.
  • Adjustments on hold-downs should be checked frequently to assure that the tube is held to the rubber sill as tight as possible.
  • The curtain material can be kept clean by using water and a mild detergent along with a soft brush or sponge.
  • All minor cuts and punctures in the curtain material should be patched immediately with Patch Kit No. 24090004 that was furnished with the door.
  • If cuts or punctures exceed two feet horizontally, consult the factory.

Periodic Inspection

It is recommended that a yearly inspection program be set up with your maintenance crew for the inspection of your door and its components.

After any unusual conditions that the door is exposed to, such as severe winds, storms, etc., a thorough inspection should be made before attempting to operate the door.

Some of the major components are:

  • Drive Chains (Should be replaced every 5 years.)
  • Sprockets
  • Gearboxes - While the oil is drained from the larger gearbox, remove the inspection plate opposite the final output shaft and inspect the gears for cracks, missing teeth and excessive wear.
  • Keys on Shafts
  • Cam Rollers
  • Motor Couplings
  • Brakes on Motors
  • Counterweight Cables
  • Counterweight Pulleys and Brackets
  • Curtain (Check for deterioration.)
  • Tube
  • Guide Rails
  • Other Structural Components

CAUTION - When any signs of wear or distortion on any of the components appear, it is recommended that they be replaced immediately.

Warranty

Except for the flexible curtain and except as warranted by manufacturers of accessories and parts, the Company warrants that the products sold hereunder, including all accessories and parts supplied by Company, will conform in all material respects to the description of the products contained in the Quote, the blueprints and drawings and that the products will be free from defects in materials and workmanship under normal use and service for a period of one (1) year (or for such longer period of time as is specified herein or in the Quote with respect to any particular product) from the date of shipment (the “Warranty Period”). Company warrants the flexible curtain for a period of five years under normal use and service, its obligation as to the flexible curtain being limited to replacing said curtain, FOB Fostoria, Ohio, at a cost to Customer equal to Company’s quoted price at time of replacement less 1/60th of said quoted price for each full month remaining of the five year warranty period.